ROXSTA cube mini S

Application

  • Discounters / organic shops / retail up to 1,000 m²
  • MT cabinets open: up to 25 m / closed: up to 50 m
  • 1-2 LT cold rooms

Capacities

(t0 MT -5 °C / t0 LT -30 °C / tGC 38 °C)

  • Medium temperature 15…90 kW
  • Low temperature 0…17 kW

Details

  • Trans- & subcritical application
  • 1 IT* & 2 MT (LSPM*) / 0-1 LT (ME*) – IQ module
  • Capacity control – CRII (MT/IT*) / Inverter* (LT)
  • Active oil management – TECO2mulator
  • TECO2nditioner
  • Receiver volume 84 L
  • Indoor & outdoor* installation
  • Mounted safety valves incl. blow off line*
  • Efficiency – Parallel compressor / LSPM motor / Ejector*
  • Heat recovery stand-alone*

* optional

Design pressure

  • 30/60 bar suction line (LT)
  • 45/60 bar suction line (MT)
  • 60 bar medium pressure
  • 120/130 bar high pressure

Back to CO2 overview