ROXSTA cube mini S
Application
- Discounters / organic shops / retail up to 1,000 m²
- MT cabinets open: up to 25 m / closed: up to 50 m
- 1-2 LT cold rooms
Capacities
(t0 MT -5 °C / t0 LT -30 °C / tGC 38 °C)
- Medium temperature 15…90 kW
- Low temperature 0…17 kW
Details
- Trans- & subcritical application
- 1 IT* & 2 MT (LSPM*) / 0-1 LT (ME*) – IQ module
- Capacity control – CRII (MT/IT*) / Inverter* (LT)
- Active oil management – TECO2mulator
- TECO2nditioner
- Receiver volume 84 L
- Indoor & outdoor* installation
- Mounted safety valves incl. blow off line*
- Efficiency – Parallel compressor / LSPM motor / Ejector*
- Heat recovery stand-alone*
* optional
Design pressure
- 30/60 bar suction line (LT)
- 45/60 bar suction line (MT)
- 60 bar medium pressure
- 120/130 bar high pressure