ROXSTA cube mini
Application
- Discounters /organic shops /retail up to 1,000 m²
- MT cabinets open: up to 25 m / closed: up to 50 m
- 1-2 LT cold rooms
Capacitiesa
(t0 MT -5 °C / t0 LT -30 °C / tGC 38 °C)
- Medium temperature 12…50 kW
- Low temperature 0…10 kW
Details
- Trans- & subcritical application
- 2 MT / 0-1 LT – different versions for capacity control
- Indoor & outdoor installation
- Noise reduction 10 / 15 dBA
- Heat recovery integrated or stand-alone
- Receiver volume 80 L
Design pressure
- 30/60 bar suction line (LT)
- 45/60 bar suction line (MT)
- 45/60 bar medium pressure
- 120/130 bar high pressure